We offer several models of data loggers that have universal inputs that can accept a variety of different sensors and signals. They offer the most flexibility in allowing the logger to be configured to measure several different parameters as the same time or allowing the logger to be easily re-used in different applications as needs change. These data loggers can typically be configured to accept thermocouple, RTD and thermistor inputs for temperature, voltage inputs, 4-20 mA current measurements, resistance measurements, low level signals from force or strain gauges and digital or counter inputs.
Universal Input Data Loggers
- General Purpose Data Loggers with Univeral Inputs
- dataTaker DT80 Series - Up to 15 Inputs with USB, Serial and Ethernet Interfaces
- dataTaker DT800 - Up to 42 Inputs with Ethernet and Serial Interfaces
- dataTaker DT50 Series
- dataTaker DT500/DT600 Series - Up to 90 Inputs with Serial Interface
- Grant Squirrel SQ2020/SQ2040 - Up to 32 Inputs with USB Interface
- Nimtech FrontDAQ - High Speed with 20 Inputs and an A/D per channel
- Fourier Systems DaqPRO - 8 Inputs with USB Interface
General Purpose Data Loggers with Universal Inputs

dataTaker DT80 Series |

dataTaker DT800 |

dataTaker DT50 Series |
The DT80 series data loggers have up to 5 low-voltage input channels that are suitable for voltage, 4-20mA, thermocouple, RTD, thermistor, resistance or frequency measurements. and a USB memory slot for easy data transfer. The DT80 Series are stand-alone data loggers that connect to a PC via Ethernet, USB, or RS-232. |
The DT800 data logger is has 12 to 42 analog input channels suitable for voltage, 4-20mA, thermocouple, RTD, thermistor, resistance or frequency measurements, 16 digital channels, and 1 serial sensor channel. The DT800 stores up to 130,000,000 data points and has an ATA Flash card slot for removable data storage. |
The DT50 series data loggers have up to 5 low-voltage input channels that are suitable for voltage, 4-20mA, thermocouple, RTD, thermistor resistance or frequency measurements. The DT50 series data loggers also have digital and counter inputs, stores up to 130,000 points in internal memory, and require an RS-232 port for connection to a PC. |
| DT80 |
5 to 15 analog inputs, 12 digital channels, 1 serial sensor channel plus built in display |
|
DT50 |
5 to 10 analog inputs, 5 digital channels, 3 counter channels, SRAM PC Card slot for Removable Data Storage |
| DT81 |
1 to 3 analog inputs, 4 digital channels, 4 counter channels |
DT51 |
1 to 3 analog inputs, 4 digital channels, 3 counter channels |

dataTaker DT500/DT600 Series |

Grant Squirrel SQ2020/SQ2040 Series |
The DT500/DT600 series data loggers have 10 to 30 analog input channels suitable for voltage, 4-20mA, thermocouple, RTD, thermistor, resistance or frequency measurements plus 4 digital channels and 3 counter channels. Each store up to 1,390,000 data points and have an SRAM PC card slot for removable data storage. Optional expansion modules allow for up to 90 analog inputs |
The Grant Squirrel SQ2020/SQ2040 series data loggers are capable of sub-second logging and concurrent sampling. With 16 MB of internal memory, the Grant Squirrel SQ2020/SQ2040 series data loggers can log approximately 1,000,000 to 2,000,000 readings that can be downloaded to a removable MMC memory card. Inputs can be used with thermistor, thermocouple and RTD temperature sensors and 4-20mA instruments or resistance measurements. |
| DT500 |
±2.5 V Input Measurement Range |
SQ2020-1F8 |
Up to 8 differential or 16 single ended analog inputs with a single ADC |
| DT505 |
±100 V Input Measurement Range |
SQ2020-2F8 |
Up to 8 differential or 16 single ended analog inputs with two ADC's |
| DT600 |
±2.5 V Input Measurement Range, with built-in display |
SQ2040-2F16 |
Up to 16 differential or 32 single ended analog inputs with two ADC's |
| DT605 |
±100 V Input Measurement Range, with built-in display |
SQ2040-4F16 |
Up to 16 differential or 32 single ended analog inputs with four ADC's |

Nimtech FrontDAQ |

Fourier Systems DaqPRO |
The Nimtech FrontDAQ data logger has 20 analog input channels suitable for voltage, 4-20 mA, resistance, thermocouple or RTD measurements plus 20 digital channels and 4 analog outputs. The Nimtech FrontDAQ data logger can sample at 7.7 kHz per channel and store data to CompactFLASH™ memory. The Nimtech FrontDAQ data logger is network-ready and incorporates an internal web server for setting up and viewing data. |
The Fourier Systems DaqPRO data logger has 8 input channels that measure voltage, current, thermocouples, and RTD's. The Fourier Systems DaqPRO data logger can log up to 4000 samples / sec and has 512 kB of local memory. The graphical display allows for stand-alone set-up and operation. |
|